230V



Take Control of the
Power Environment


The Axess Elite is a complete power management solution that provides remote insight and control of the electrical power consumed by an underlying device. It enables the switching of devices in various power modes, each with different power usage characteristics related to device performance. Giving technicians the ability to easily manage their installs remotely and limit service calls.

  • IP enabled two-way communication
  • Displays real-time power and energy usage
  • Collects rack temperature, voltage, and current draw measurements
  • Displays a log file for advanced monitoring
  • Non-sacrificial components
  • Advanced Series Mode® surge elimination technology
  • Impedance Tolerant EMI/RFI Filter
  • COUVS® catastrophic over/under voltage shutdown
  • SurgeX ICE® inrush current elimination
  • Magnetic shielding steel enclosure
  • 9’ grounded 3-wire cord

Models: 
SX-AX10Ei, SX-AX16Ei

  • Overview +


    The Axess Elite provides IP addressable two-way communication, manages system energy usage, can sequence individual outlets, monitors power usage at the system level, controls expansion units from the master unit, and monitors a system’s energy consumption by each connected device. It integrates with most major control systems, including AMX and Crestron.

    The user-friendly GUI lets technicians hard reboot locked up equipment, recycle power, schedule automatic triggers to AutoPing devices, monitor individual outlets and power settings to eliminate the time and costs associated with sending a technician on-site.

    The Axess Elite also features Advanced Series Mode® technology that eliminates all surge energy to guarantee connected equipment is protected from surges, spikes, electrical transients, and noise without producing harmful ground contamination or common-mode disturbances. It is the most advanced technology available to safeguard AV equipment.




  • Specifications +


    Parameters

    Specification

    Load Rating

    10A/16A total load; 10A per outlet (SX-AX10Ei / SX-AX16Ei)

    Power Requirement (no load)

    5 Watts

    Surge Let-through Voltage (6000 Volt Surge)

    0 Volts

    UL 1449 Adjunct Classification Test Results

    1000 Surges, 6000 Volts, 3000 Amps, B3 pulse; measured suppressed voltage, 170 Volts; no failures

    Maximum Applied Surge Voltage

    6000 Volts *

    Maximum Applied Surge Current

    Unlimited (due to current limiting) *

    Maximum Applied Surge Energy

    Unlimited (due to current limiting) *

    Endurance (C62.41-1991 category B3 pulses)

    1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000

    ­

    EMI/RFI Filter

    Normal mode (50Ω load)

    >20 dB 35 kHz – 50 MHz
    >30 dB 170 kHz – 20 MHz
    25 dB @ 100 KHz, 40dB @ 300 KHz
    56 dB @ 3 MHz, 30 dB @ 30 MHz

    Common Mode (50Ω load)

    >10 dB 300 kHz – 50 MHz
    >20 dB 1.5 MHz – 50 MHz
    10 dB @ 300 KHz, 18 dB @ 1 MHz
    30 dB @5 MHz, 20 dB @ 20 MHz

    Under-Voltage Auto Shutdown

    Adjustable from 160V to 210V, or disabled.

    Over-Voltage Auto Shutdown

    Adjustable from 240V to 300V

    Over-Current Auto Shutdown

    Adjustable from 1A to 20A, or disabled.

    Over-Temperature Auto Shutdown

    Adjustable from 21°C to 38°C, or disabled.

    Measurement Accuracy

    Voltage

    ± 1% from 90 – 300 VRMS

    Current

    ± 1% from 0.1 – 20 ARMS (Resistive)

    Power

    ± 5% from 0.1 2400 WRMS (Resistive)

    Energy

    ± 5% kWh

    Temperature

    ± 2C from -25 105C

    Network Port

    10/100 Ethernet connection on Female RJ-45, Auto Negotiating with 10/100/1000 network connections with Link and Activity LEDs

    Serial Port

    RS-232 on Female 9-pin D-subminiature, DCE

    Temperature Sensor Input

    2 x screw terminal

    Auxiliary Relay Outputs

    (2) 3 x screw terminal

    Contact Closure Input

    2 x screw terminal

    Dimensions

    4.5cm H x 48.3cm W x 33.7cm D

    Weight

    5.9 kg

    Temperature Range:

    5C to 35C

    Humidity Range

    0% to 95% R.H. Non-condensing

    Agency Listings

    CE applicable country certifications. Contact your SurgeX representative for details.

    * 1.2 x 50 microsecond industry standard combination wave surge as per IEEE C62.41

    ** Specifications subject to change without notice

    *CAUTION: Do not install this device if there is not at least 10 meters (30 feet) or more between the electrical outlet and the electrical service panel.